Connect the blue wire (common) to the common connection on the door position switch. IEI 232e Standalone Installation/Programming Manual Figure 6 Wiring 232e Keypad to Electric Strike 4.4 Shunting a Normally Closed Zone Use the following steps to employ the 232e keypad to shunt a normally closed zone: 1. Connect the black wire (V-) to the negative on the Maglock, and then connect them to the negative on the power supply. Connect the gray wire (normally closed) to the positive on the maglock. Connect the red wire (V+) to the blue wire (common), and then connect them to the positive on the power supply. IEI 232e Standalone Installation/Programming Manual 4.2 Wiring the 232e Keypad to a Maglock (FailSafe) Use the following steps to connect the 232e keypad to a Maglock (Fail-Safe): 1. Wiring Figure 4 232e Connector and Wire Harness 4. IEI 232e Standalone Installation/Programming Manual 4. Mounting height can vary depending on requirements. To properly size the mounting and wire access hole, use the installation template on the last page of this manual and on the unit’s container. In addition, it can be flush mounted directly to the wall surface by cutting a hole in the wall. Mounting The keypad is designed to be flush mounted using a standard singlegang electrical box. IEI 232e Standalone Installation/Programming Manual 3. IEI 232e Standalone Installation/Programming Manual Figure 1 Mounting a Sentrol 3012 Tamper Switch Figure 2 Mounting a Sentrol 3025T Tamper Switch Document # 6054004, Rev. In addition, all wires and cables used must be stranded and shielded U.L. This system must be installed in accordance with the National Electrical code (NFPA70), local codes, and the authorities having jurisdiction. This section contains information regarding all the requirements necessary to meet U.L. IEI 232e Standalone Installation/Programming Manual Section 3. Specifications Parameter Range/Description Voltage 10-30 VDC, 12-24 VAC Current and Add 20 mA for each alarm relay Environment Indoor and Outdoor Temperature Tolerance -20 ☏ to 130 ☏ Dimensions 4.5" H x 2.75" W x 0.60" D Main Relay (Form C) Alarm Relays: Alarm Shunt, Propped Door, Forced Door Relays (Form C) Document # 6054004, Rev. IEI 232e Standalone Installation/Programming Manual 2. IEI 232e Standalone Installation/Programming Manual 1. Requirements Specifications Mounting Wiring 5.1 Wire Harness Configuration 5.2 Wiring the 232e Keypad to a Maglock (Fail-Safe) 5.3 Wiring the 232e Keypad to an Electric Strike (Fail-Secure) 5.4 Shunting a Normally Closed Zone 5. IEI 232e StandaloneTM Keypad Installation/ Programming Manual Contents Section 1: Section 2: Section 3: Section 4: Section 5: Section 6: Section 7: Section 8: Section 9: Section 10: Features and Product Description 1.1 Features 1.2 Product Description U.L.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |